VMware ESXiサーバとして動作しているhp ProLiant DL380p Gen8サーバのiLOをアップデートした。
まず、ESXi上から、iLOのバージョンと、iLOに割り当てられているIPアドレスを確認するため「hponcfg」コマンドを実行
/tmp # /opt/hp/tools/hponcfg -g
HP Lights-Out Online Configuration utility
Version 4.4-0 (c) Hewlett-Packard Company, 2014
Firmware Revision = 1.40 Device type = iLO 4 Driver name = hpilo
iLO IP Address: 172.17.15.99
Host Information:
Server Name: esxi1.osakana.local
Server Serial Number: SGH421XXXX
/tmp #
iLOのアップデータファイル CP025110.scexe を、/tmpに配置し、実行権限を与え、実行。
/tmp # chmod a+x CP025110.scexe
/tmp # ./CP025110.scexe
OS Version found [5.5.0]
sh: 6.0=./ESXi_5.5: unknown operand
./CP025110.scexe: Okay process the path [./ESXi_5.5 6.0]
sh: 6.0: unknown operand
./CP025110.scexe: Update flash engine from ./ESXi_5.5 6.0
sh: 6.0/clean_target_location.sh: unknown operand
sh: 6.0/copy_FE_to_target_location.sh: unknown operand
Copy Flash Engine files from [./ESXi_5.5 6.0] to [/tmp/sctmpdir4924713]
cp: './ESXi_5.5' and './ESXi_5.5' are the same file
cp: can't stat '6.0/*': No such file or directory
iLO Flasher v1.0.2-2 for VMware ESXi (Jan 7 2014)
(C) Copyright 2002-2014 Hewlett-Packard Development Company, L.P.
Firmware image: ./ilo4_203.bin
Current iLO 4 firmware version 1.40; Serial number ILOSGH421XXXX
Component XML file: ./CP025110.xml
./CP025110.xml reports firmware version 2.03
This operation will update the firmware on the
iLO 4 in this server with version 2.03.
Continue (y/N)?y
Current firmware is 1.40 (Jan 14 2014 00:00:00)
Firmware image is 0x1001b1c(16784156) bytes
Committing to flash part...
******** DO NOT INTERRUPT! ********
Flashing is underway... 100 percent programmed. \
Succeeded.
***** iLO 4 reboot in progress (may take up to 60 seconds.)
***** Please ignore console messages, if any.
iLO 4 still rebooting. Try again...
iLO 4 reboot completed.
/tmp #
firmwareのバージョンが上がっていることを確認。
/tmp # /opt/hp/tools/hponcfg -g
HP Lights-Out Online Configuration utility
Version 4.4-0 (c) Hewlett-Packard Company, 2014
Firmware Revision = 2.03 Device type = iLO 4 Driver name = hpilo
iLO IP Address: 0.0.0.0
Host Information:
Server Name: esxi1.osakana.local
Server Serial Number: SGH421XXXX
/tmp #
・・・と、実行が早すぎたようで、DHCPで割り当てているIPアドレスが「0.0.0.0」となっている。
時間をおいて再実施
/tmp # /opt/hp/tools/hponcfg -g
HP Lights-Out Online Configuration utility
Version 4.4-0 (c) Hewlett-Packard Company, 2014
Firmware Revision = 2.03 Device type = iLO 4 Driver name = hpilo
iLO IP Address: 172.17.15.99
Host Information:
Server Name: esxi1.osakana.local
Server Serial Number: SGH421XXXX
/tmp #
これで、問題なしですね。