Manual checks that can be done using Upgrade ONTAP documentation
メッセージ
Manual validation checks need to be performed. Refer to the Upgrade Advisor Plan or the "What should I verify before I upgrade with or without Upgrade Advisor" section in the "Upgrade ONTAP" documentation for the remaining validation checks that need to be performed before update. Failing to do so can result in an update failure or an I/O disruption.
解決策
Refer to the Upgrade Advisor Plan or the "What should I verify before I upgrade with or without Upgrade Advisor" section in the "Upgrade ONTAP" documentation for the remaining validation checks that need to be performed before update.
ONTAP API to REST transition warning
メッセージ
NetApp ONTAP API has been used on this cluster for ONTAP data storage management within the last 30 days. NetApp ONTAP API is approaching end of availability.
解決策
Transition your automation tools from ONTAP API to ONTAP REST API. CPC-00410 - End of availability: ONTAPI : https://mysupport.netapp.com/info/communications/ECMLP2880232.html
Ensure that the NX-OS (cluster network switches), IOS (management network switches), and reference configuration file (RCF) software ersions are compatible with the target Data ONTAP release.
Refer to http://mysupport.netapp.com/NOW/download/software/cm_switches/ and http://mysupport.netapp.com/NOW/download/software/cm_switches_ntap/ for more details.
Name Service Configuration DNS Check
メッセージ
None of the configured DNS servers are reacjanle for the following Vservers: 名前. There might be other Vservers for DNS servers are not reachable.
解決策
Delete the DNS server, or verify that the DNS status is "up". Delete the DNS configuration for the Vservers which do not have "dns" as a configured source in the ns-switch database.
NFS mounts
メッセージ
This cluster is serving NFS clients. If NFS soft mounts are used, there is a possibility of frequent NFS timeouts and race conditions that can lead to data corruption during the upgrade
解決策
Use NFS hard mounts, if possible
CIFS status
メッセージ
CIFS is currently in use. Any unprotected sessions may be affected with possible loss of data.
解決作
Stop all unprotected CIFS workloads before performing the update. To list the unprotected CIFS workloads, run the command: vserver cifs session show -continuously-available No, Partial
ontap9121::> cluster image show-update-progress
Estimated Elapsed
Update Phase Status Duration Duration
-------------------- ----------------- --------------- ---------------
Pre-update checks completed 00:10:00 00:00:38
Details:
Pre-update Check Status Error-Action
-------------------- ----------------- --------------------------------------
AMPQ Router and OK N/A
Broker Config
Cleanup
Aggregate online OK N/A
status and parity
check
Application OK N/A
Provisioning Cleanup
Autoboot Bootargs OK N/A
Status
Backend OK N/A
Configuration Status
Boot Menu Status OK N/A
CIFS compatibility OK N/A
status check
Capacity licenses OK N/A
install status check
Check For SP/BMC OK N/A
Connectivity To
Nodes
Check LDAP fastbind OK N/A
users using
unsecure connection.
Cloud keymanager OK N/A
connectivity check
Cluster health and OK N/A
eligibility status
Cluster/management OK N/A
switch check
Compatible New OK N/A
Image Check
Current system OK N/A
version check if it
is susceptible to
possible outage
during NDU
Data ONTAP Version OK N/A
and Previous
Upgrade Status
Data aggregates HA OK N/A
policy check
Disk status check OK N/A
for failed, broken
or non-compatibility
Duplicate Initiator OK N/A
Check
Encryption key OK N/A
migration status
check
External OK N/A
key-manager with
legacy KMIP client
check
External keymanager OK N/A
key server status
check
Infinite Volume OK N/A
availibility check
Logically over OK N/A
allocated DP
volumes check
Manual checks that Warning Warning: Manual validation checks
can be done using need to be performed. Refer to the
Upgrade ONTAP Upgrade Advisor Plan or the "What
documentation should I verify before I upgrade with
or without Upgrade Advisor" section
in the "Upgrade ONTAP" documentation
for the remaining validation checks
that need to be performed before
update. Failing to do so can result
in an update failure or an I/O
disruption.
Action: Refer to the Upgrade Advisor
Plan or the "What should I verify
before I upgrade with or without
Upgrade Advisor" section in the
"Upgrade ONTAP" documentation for the
remaining validation checks that need
to be performed before update.
MetroCluster OK N/A
configuration
status check for
compatibility
Minimum number of OK N/A
aggregate disks
check
NAE Aggregate and OK N/A
NVE Volume
Encryption Check
NDMP sessions check OK N/A
NFS mounts status OK N/A
check
NVMe over Fabrics OK N/A
license check
Name Service OK N/A
Configuration DNS
Check
Name Service OK N/A
Configuration LDAP
Check
Node to SP/BMC OK N/A
connectivity check
OKM/KMIP enabled OK N/A
systems - Missing
keys check
ONTAP API to REST Warning Warning: NetApp ONTAP API has been
transition warning used on this cluster for ONTAP data
storage management within the last 30
days. NetApp ONTAP API is approaching
end of availability.
Action: Transition your automation
tools from ONTAP API to ONTAP REST
API. For more details, refer to
CPC-00410 - End of availability:
ONTAPI
https://mysupport.netapp.com/info/
communications/ECMLP2880232.html
ONTAP Image OK N/A
Capability Status
OpenSSL 3.0.x OK N/A
upgrade validation
check
Openssh 7.2 upgrade OK N/A
validation check
Pre-Update OK N/A
Configuration
Verification
RDB Replica Health OK N/A
Check
Replicated database OK N/A
schema consistency
check
Running Jobs Status OK N/A
SAN and NVMe LIF OK N/A
Online Check
SAN compatibility OK N/A
for manual
configurability
check
SAN kernel agent OK N/A
status check
Secure Purge OK N/A
operation Check
Shelves and Sensors OK N/A
check
SnapLock Version OK N/A
Check
SnapMirror OK N/A
Synchronous
relationship status
check
SnapMirror OK N/A
compatibility
status check
Supported platform OK N/A
check
Target ONTAP OK N/A
release support for
FiberBridge 6500N
check
Upgrade Version OK N/A
Compatibility Status
Verify all bgp OK N/A
peer-groups are in
the up state
Verify that e0M is OK N/A
home to no LIFs
with high speed
services.
Volume Conversion OK N/A
In Progress Check
Volume move OK N/A
progress status
check
Volume online OK N/A
status check
iSCSI target portal OK N/A
groups status check
Overall Status Warning Warning
61 entries were displayed.
ontap9121::>
「set diag」コマンドでdiagモードに移行したあとで「system node systemshell -node localhost -command ls /」を実行してどうなるかを確認する。
::> set diag
Warning: These diagnostic commands are for use by NetApp personnel only.
Do you want to continue? {y|n}: y
::*> system node systemshell -node localhost -command ls /
(system node systemshell)
Error: command failed: Error: Account currently locked. Contact the storage
administrator to unlock it.
::*>
ONTAPシミュレータ 9.12.1以降は上記の様な「Error」となると思われる。
5) diagアカウントのロックを解除
上記のエラーはdiagアカウントがロック状態であることが原因であるため、ロックを解除する。
「security login show -user-or-group-name diag」を実行して現在の状態を確認(ONTAPバージョンによっては “security login show -username diag”)
::*> security login show -user-or-group-name diag
Vserver: Default
Second
User/Group Authentication Acct Authentication
Name Application Method Role Name Locked Method
-------------- ----------- ------------- ---------------- ------ --------------
diag console password admin yes none
::*>
「Acct Lock: yes」であるためロックされていることを確認できる。
「security login unlock -username diag」を実行する
::*> security login unlock -username diag
Error: command failed: The admin password is not set. Use the "security login
password" command to set the password, then try the command again.
::*>
::*> security login password -username admin
Enter your current password: <初期設定前であればエンターキー入力>
Enter a new password: <新しいパスワード>
Enter it again: <新しいパスワード>
::*> security login unlock -username diag
::*>
ロック解除に成功した場合、なにも表示されないため、確認のために「security login show -user-or-group-name diag」を実行する
::*> security login show -user-or-group-name diag
Vserver: Default
Second
User/Group Authentication Acct Authentication
Name Application Method Role Name Locked Method
-------------- ----------- ------------- ---------------- ------ --------------
diag console password admin no none
::*>
6) 現状のディスク構成を確認
現状のディスク構成を確認するために「system node systemshell -node local -command “ls -l /sim/dev/,disks”」を実行する。
実行後「system node systemshell -node local -command “ls -l /sim/dev/,disks”」を実行し、ファイルが削除されたことも確認します。
::*> system node systemshell -node local -command "cd /sim/dev/,disks; sudo rm *"
::*> system node systemshell -node local -command "ls -l /sim/dev/,disks"
total 0
::*>
ontap9121::> storage aggregate add-disks -aggregate aggr0_ontap9121_01 -diskcount 1
Warning: Aggregate "aggr0_ontap9121_01" is a root aggregate. Adding disks to
the root aggregate is not recommended. Once added, disks cannot be
removed without re-initializing the node.
Do you want to continue? {y|n}: y
Info: Disks would be added to aggregate "aggr0_ontap9121_01" on node
"ontap9121-01" in the following manner:
First Plex
RAID Group rg0, 4 disks (block checksum, raid_dp)
Usable Physical
Position Disk Type Size Size
---------- ------------------------- ---------- -------- --------
data NET-1.11 FCAL 8.79GB 8.82GB
Aggregate capacity available for volume use would be increased by 7.91GB.
Do you want to continue? {y|n}: y
ontap9121::> storage aggregate show
Aggregate Size Available Used% State #Vols Nodes RAID Status
--------- -------- --------- ----- ------- ------ ---------------- ------------
aggr0_ontap9121_01
15.03GB 7.88GB 48% online 1 ontap9121-01 raid_dp,
normal
ontap9121::> df -A -h
Aggregate total used avail capacity
aggr0_ontap9121_01 15GB 7320MB 8069MB 48%
aggr0_ontap9121_01/.snapshot 810MB 0B 810MB 0%
2 entries were displayed.
ontap9121::>
SAN Transportについて、何の変哲もないiSCSIストレージを、ESXiサーバとWindowsサーバの両方につなげただけでも使えるのかな、と検証してみようとした。
(上記画像はVMwareから転載)
まあ、実機の環境がなかったので、vSphere仮想マシンのWindowsサーバからiSCSI接続して構築してみたところ、commvaultの場合は「SAN access is only supported for physical machines.」というメッセージでバックアップさせてくれなかった。
Event Code: 91:248
Severity: Minor
Program: vsbkp
Description:
Unable to open the disks for virtual machine [仮想マシン名] for SAN access. SAN access is only supported for physical machines.